Padmount Supply

Home / Products / Medium Voltage Cable / 15kV cable for sale

15kV cable for sale

15kV MV-105 cable with 133 percent EPR insulation is sold by the reel in sizes from 2 AWG to 2000 kcmil. The table below gives the diameters, weights and ampacities from a maker spec sheet, and the price ranges are published distributor estimates, not our quotes. We quote the exact size, length and delivered price for your job.

Updated November 17, 2026

Request a 15kV cable quoteOr call 786 220 2801.

What this cable is

The reference construction is a Type MV-105 single conductor with Class B compressed stranded copper, a semi-conducting conductor shield, 220 mil EPR insulation at the 133 percent insulation level, a strippable insulation shield, a copper tape shield and a PVC jacket. It is dual rated UL and CSA.

It can run continuously at 105 C conductor temperature, with 140 C for emergency overload and 250 C for short circuit. The sheet lists it for wet and dry locations, conduit, duct, trays (1/0 and larger) and direct burial when a grounding conductor is installed close by.

Size table, copper MV-105 15kV 133 percent

Nominal values from the Southwire spec 46302 read in November 2026. Ampacity is for the 90 and 105 C ratings, in duct and in free air, per the sheet. Always check the sheet for your exact stock number.

SizeDiameter over insulation, inCable OD, inWeight, lb per 1000 ftDuct ampacity 90/105 C, AAir ampacity 90/105 C, A
1/0 AWG0.8401.080820195/210215/240
2/0 AWG0.8841.124934220/235245/275
4/0 AWG0.9901.2301247285/305325/360
250 kcmil1.0441.2841403310/335360/400
350 kcmil1.1471.3871780375/400435/490
500 kcmil1.2521.4922313450/485535/600
750 kcmil1.4641.7643329545/585670/745
1000 kcmil1.6131.9134209615/660770/860

Diameter over insulation is the number that matches an elbow or termination, see the loadbreak elbow page.

Published price per foot ranges

A distributor published these 15kV estimates in January 2026. They are market ranges before cut, reel and freight charges, not a quote, and copper moves with the metal market. The first range is copper and the second is aluminum.

The same article puts a typical commercial job on 250 to 500 kcmil copper EPR 15kV cable at about 18 to 55 dollars per foot, and says copper prices can swing 20 to 40 percent inside a year.

SizeCopper, dollars per footAluminum, dollars per foot
1/07.50 to 16.005.20 to 11.00
250 kcmil12.00 to 26.008.50 to 18.00
500 kcmil22.00 to 48.0016.00 to 35.00
1000 kcmil42.00 to 88.0032.00 to 65.00

Stock sizes and what adds to the price

Southwire marks 2, 1/0, 2/0, 4/0, 250, 350, 500, 600, 750 and 1000 as standard stock items on this sheet. 1 AWG, 3/0 and the sizes from 1250 kcmil up are not marked stock, so expect a longer wait on those.

The distributor article lists cut charges of 50 to 200 dollars per cut, reel charges of 100 to 500 dollars per reel and freight of 200 to 800 dollars per order as common add ons. Ask for them on the quote.

Copper or aluminum

Aluminum 15kV MV-105 cable is sold in the same sizes. It costs less per foot but carries less current at the same size, so a feeder may need the next size up. The primary URD page has the aluminum concentric neutral numbers.

What to send for a quote

  • Voltage class and insulation level, 100 or 133 percent
  • Conductor size and material
  • Shield type, tape or wire
  • Length and reel size
  • Duct, tray or direct burial
  • Delivery ZIP code
Request a 15kV cable quoteOr call 786 220 2801.

Common questions

What does 133 percent insulation level mean

It is the insulation thickness class for systems where a ground fault may last longer than a minute, such as ungrounded or high impedance grounded systems. Your engineer or utility sets the level.

How much is 15kV cable per foot

One distributor published 7.50 to 16.00 dollars per foot for 1/0 copper and 22.00 to 48.00 for 500 kcmil copper in January 2026, before cut, reel and freight charges. Aluminum runs lower.

What is the ampacity of 4/0 15kV cable

The Southwire copper MV-105 sheet lists 285/305 A in duct and 325/360 A in free air at the 90 and 105 C ratings.

Can I bury 15kV MV-105 cable directly

The sheet lists it for direct burial when a grounding conductor is installed in close proximity. Follow your engineer and the code.

Related pages

Sources

Market figures are public asking prices and published industry figures, dated where the source gives a date. They are not our prices. A quote from us is a delivered price for a specific unit.

CallGet a quote