Primary URD is the jacketed concentric neutral cable that feeds pad mounted transformers underground. This page lists the 15kV aluminum, 133 percent EPR, one-third neutral construction from a maker spec sheet by size. Delivered price depends on size, reel and market, so we quote each job.

Updated November 17, 2026

What the cable is

The sheet describes a single conductor with moisture blocked Class B compressed aluminum, 220 mil EPR insulation at the 133 percent level, a strippable insulation shield, a helically applied soft drawn bare copper one-third concentric neutral and a black LLDPE jacket with red stripes.

It is rated for 105 C continuous, 140 C emergency and 250 C short circuit. The sheet lists it for wet and dry areas, conduit, duct and direct burial, and cites ICEA S-94-649, AEIC CS-8 and Rural Utility Service bulletin 1728F-U1. It can be marked UL MV-90 when specified.

Size table, 15kV aluminum one-third neutral

Nominal values from Southwire spec 81069 read in November 2026. Ampacity is at 90 C, single circuit, from the sheet's ICEA P-117 basis.

SizeDiameter over insulation, inNeutral wiresCable OD, inWeight, lb per 1000 ftDuct ampacity, ABuried ampacity, A
1/0 (19 strand)0.8306 x 14 AWG1.158603155195
2/00.8737 x 14 AWG1.201668180220
4/00.96811 x 14 AWG1.286880235285
250 kcmil1.04413 x 14 AWG1.392985256309
350 kcmil1.14718 x 14 AWG1.4951209310370
500 kcmil1.27525 x 14 AWG1.6731593370445
750 kcmil1.45824 x 12 AWG1.8842203460525
1000 kcmil1.61320 x 10 AWG2.1172696520575

Bend radius and pulling

Plan the route with the sheet's limits, since a tight pad mount vault leaves little room.

SizeMinimum bend radius, inMaximum pull tension, lb
1/08.1633
2/08.4798
4/09.01269
250 kcmil9.71500
350 kcmil10.52100
500 kcmil11.73000
750 kcmil13.24500
1000 kcmil14.86000

Pull tension assumes the pulling eye is connected directly to the conductor.

One-third neutral or full neutral

The neutral on this sheet carries six 14 AWG wires on 1/0. Southwire also lists 1/0 aluminum 15kV products with sixteen 14 AWG neutral wires, which is a heavier neutral, and a 175 mil 100 percent TRXLPE option. Your utility specification decides the neutral, the insulation level and the insulation material, so confirm all three before ordering.

On the sheet only 4/0 and 750 kcmil carried stock numbers in November 2026, and the other sizes were listed to be assigned, so delivery depends on the size and the maker's schedule.

Pick the matching elbow

Diameter over insulation sets the elbow size. 1/0 at 0.830 inch and 4/0 at 0.968 inch sit in different elbow housing ranges, see the loadbreak elbow page.

What to send for a quote

  • Voltage class and insulation level
  • Conductor size and material
  • Neutral size, one-third or full
  • Insulation material, EPR or TRXLPE
  • Length and reel size
  • Delivery ZIP code

Common questions

What is primary URD cable

Underground residential distribution cable at medium voltage, with a concentric neutral of copper wires under a jacket. It is the usual feed to a pad mounted transformer.

What is the ampacity of 1/0 aluminum 15kV URD

The Southwire sheet lists 155 A in duct and 195 A directly buried at 90 C for 1/0 aluminum with a one-third neutral.

What is the OD of 4/0 15kV URD cable

About 1.286 inches on the sheet, at about 880 pounds per 1000 feet.

Is a one-third neutral enough

It depends on the fault current and the utility rules. Follow the utility or engineer specification.