Home / Products / Data center power / Static transfer switches for sale, Cyberex, Liebert STS2 and Eaton
Static transfer switches for sale, Cyberex, Liebert STS2 and Eaton
A static transfer switch moves a critical load between two power sources in milliseconds using solid state switches, with no moving contacts. It is how data centers feed dual corded and single corded loads from two UPS systems. We quote new and reconditioned static transfer switches, delivered. The table below shows the published ratings for the main models.
Updated November 15, 2026
Model table
Ratings below come from maker guide specifications and datasheets. Confirm voltage and current on the nameplate of your unit.
| Model | Maker | Published ampere ratings | Published transfer detail |
|---|---|---|---|
| SuperSwitch 4 | Cyberex, ABB | 100, 200, 250, 400, 600, 800, 1000, 1200, 1600, 2000, 3000 and 4000 A | Under 4 ms in phase, under 16 ms out of phase |
| STS2 | Liebert, Vertiv | Guide specification covers 100 to 1000 A | Solid state, three pole, six pairs of SCRs, fuseless |
| WaveStar TFA | Eaton | 250, 400, 600, 800, 1000 or 1200 A | Carries 100 percent of full load continuously |
| Data center STS | Delta | 200 to 800 A at 480 V in one datasheet | Under 5 ms for synchronized sources |
| STS range | Borri | 16 A to 3000 A | See maker brochure |
We could not read a transfer time for the Liebert STS2 this run, so none is shown.
STS versus ATS
An automatic transfer switch uses mechanical contacts. Sources we read put ATS transfer at several line cycles, roughly 50 to 100 ms or more, and put an STS at single digit milliseconds, one vendor saying 4 to 8 ms. At 60 Hz a cycle is about 16.7 ms, so a 4 to 8 ms STS transfer is under half a cycle. Sources generally point STS or UPS backed transfer at IT loads with little ride through, and ATS at loads such as HVAC and lighting. An STS still needs two acceptable, synchronized sources at the moment of transfer.
Rack mount and floor standing
Smaller STS units are rack mount for single corded IT loads, while the ampere ratings in the table are floor standing units. Tell us which you need and the voltage.
Legacy and refurbished units
Cyberex and Liebert units are common in older data rooms. We quote new units and reconditioned or replacement units where available. Send the nameplate so we match the model, voltage and ampere rating.
Price and lead time
We found no published price and no published lead time for static transfer switches. We state price, condition and lead time on every quote.
What to send for a quote
- Maker, model and ampere rating, from the nameplate
- Voltage and frequency
- Number of sources and whether they are synchronized
- Rack mount or floor standing, and cable entry
- Maintenance bypass needs
- New or reconditioned, and warranty needed
- Delivery ZIP code and the date you need it on site
Common questions
What is a static transfer switch
It is a solid state switch that moves a load between two sources in milliseconds, with no moving contacts.
How fast is a static transfer switch
Cyberex lists under 4 ms in phase and under 16 ms out of phase for the SuperSwitch 4. One vendor puts STS transfer at 4 to 8 ms.
What is the difference between STS and ATS
An ATS uses mechanical contacts and takes about 50 to 100 ms or more. An STS is solid state and takes single digit milliseconds.
What ampere ratings do static transfer switches come in
Cyberex lists 100 to 4000 A, Eaton WaveStar TFA 250 to 1200 A and the Liebert STS2 guide specification covers 100 to 1000 A.
Related pages
Sources
- ABB, Cyberex SuperSwitch 4 technical data
- Vertiv, Liebert STS2 100 to 1000 A guide specification
- Eaton, WaveStar TFA STS guide specification
- Delta, data center static transfer switch 200 to 800 A
- Borri, STS brochure
- Onesto, ATS vs STS
- Power Control, STS and ATS difference
Market figures are public asking prices and published industry figures, dated where the source gives a date. They are not our prices. A quote from us is a delivered price for a specific unit.