Metal clad switchgear

Metal clad switchgear is medium voltage gear with drawout vacuum breakers, each in its own grounded compartment. IEEE C37.20.2 defines it for 4.76 to 38 kV maximum voltage and main bus ratings of 1,200 to 4,000 A. It is the usual choice for main and feeder breakers in plants, data centers and utility buildings. We source new, surplus and reconditioned lineups from the major makers and quote them delivered.

Updated November 17, 2026

What makes gear metal clad

Under IEEE C37.20.2 the main switching and interrupting device is removable, drawout. Parts such as the breaker, main bus, and incoming and outgoing connections sit in separate compartments divided by grounded metal barriers. Automatic shutters cover the primary stabs when the breaker is withdrawn, and the primary bus is insulated.

Every metal clad assembly is also metal enclosed, but not the reverse. Metal enclosed gear can use fixed devices, usually costs less and takes less room. The IEEE standard has been revised, with the 2015 edition superseded, so state the edition in your specification.

Ratings

The standard covers rated maximum voltages from 4.76 kV to 38 kV and main bus current of 1,200, 2,000, 3,000 and 4,000 A. Short circuit ratings vary by maker and line, as the table shows.

Maker and linePublished voltage and rating
Eaton VacClad-W with VCP-W breakersUp to 38 kV, 50 or 60 Hz
Siemens GM-SG5 to 27 kV, short time withstand up to 63 kA, arc resistant variant to IEEE C37.20.7 Type 2B
Powell PowlVacInterrupting ratings 25 to 63 kA, arc resistant, one or two high
ABB SafeGearUp to 15 kV, up to 50 kA, SafeGear HD to 63 kA, indoor
Schneider Electric Square D MasterCladUp to 4,000 A at 15 kV and 2,000 A at 27 kV

Figures are the makers' own published claims, read November 2026. GE PowerVac is a long standing line on the used market, and we did not find current maker data for it, so ask us about a specific unit.

Building a lineup

A lineup is a row of sections on one bus. Typical sections are the main breaker, a tie breaker, feeder breakers, a voltage transformer section and a control power transformer section. Count each breaker, note whether sections are one or two high and decide whether the room allows a front or rear access design. Send the single line diagram if you have one.

New or reconditioned, and lead times

Terrapin data from June 2026 gives 52 to 80 weeks for 15 kV gear and 78 to 104 weeks at 38 kV. Reconditioned metal clad gear is a common way around that wait and an exact match for old lineups. Electrical Trader budget ranges are on the price guide, and tests and warranty terms are on used switchgear.

Metal clad versus pad mounted

Metal clad gear lives indoors or in an e-house and uses drawout breakers. Pad mounted gear is outdoors and usually uses fuses or fault interrupters for distribution loops. Many projects use both, pad mounted gear at the utility feed and metal clad gear inside.

What to send for a quote

  • Nominal system voltage and the maximum voltage class wanted, for example 13.2 kV or 34.5 kV
  • Main bus amps and the short circuit rating in kA
  • Number of breakers, switches or ways, and the feeder schedule
  • Indoor or outdoor, and arc resistant or not
  • New, new surplus or reconditioned, and the date you need it on site
  • A photo of the nameplate if you are matching an existing lineup
  • Delivery ZIP code

Common questions

What standard defines metal clad switchgear

IEEE C37.20.2. It covers rated maximum voltages from 4.76 kV to 38 kV and main bus ratings from 1,200 to 4,000 A.

Is metal clad the same as metal enclosed

No. Metal clad needs drawout breakers and grounded barriers between compartments. Every metal clad assembly is metal enclosed, but not the reverse.

Who makes metal clad switchgear

Eaton, Siemens, ABB, Powell and Schneider Electric with Square D are the main lines we quote, plus used GE units.

How long does metal clad switchgear take to deliver

New 15 kV gear runs 52 to 80 weeks on Terrapin data from June 2026. Reconditioned gear can be much faster.