Padmount Supply

Home / Products / Substation transformers / Mobile substations for sale

Mobile substations for sale

A mobile substation is a transformer, switchgear and protection on a trailer. Buyers are utilities, plants and developers who need to restore or add capacity fast and will need the unit again. We source new, surplus and remanufactured units and quote them delivered.

Updated November 18, 2026

What you are buying

A mobile substation is a power transformer with high side and low side switchgear, protection and control built on one or more road legal trailers. A mobile transformer alone is a transformer on a trailer that connects to separate switchgear. Ask which one a seller is quoting, because the price and the site work are very different.

Typical ratings and voltages

Published ranges for the usual mobile unit.

SourceWhat it says
United RentalsMobile units typically range from 10 MVA to 100 MVA, and those under 50 MVA are the most deployable configurations for rapid response.
IEEE Winnipeg PES presentationMobile substations are generally rated 60 MVA or less. Voltage and MVA combinations are limited by DOT weight and dimension limits. A second voltage level or a load tap changer adds size and weight and cuts the MVA you can fit.
Delta StarMobile transformers up to 345 kV on the high side and portable substations up to 100 MVA at 15 to 345 kV.
Sunbelt SolomonRental units that connect to grids or sites operating at up to 230 kV.
Wind Farm BOPA 40 MVA unit at 115 kV or 138 kV is a typical wind farm mobile substation, and a late transformer is often the biggest cause of substation schedule slips.
Hitachi EnergyA 40 MVA, 150/30 kV mobile substation typically needs a few days for installation and commissioning once it is on site.

Quoted from the sources listed at the bottom of the page.

The weight limit decides the design

Road weight and dimension limits cap the MVA and the number of voltage levels. A load tap changer or a second voltage adds weight and reduces the MVA that fits. One surplus dealer listing of a 30 MVA, 69 kV primary mobile transformer gives a total weight of about 85,240 pounds, and heavier units can pass 100,000 pounds. Plan permits and the route before you commit to a unit.

Full load amps by MVA

Use these to size cable, switchgear and the feeder. Computed from the MVA and the line voltage.

MVAAmps at 13.8 kVAmps at 34.5 kVAmps at 69 kVAmps at 115 kVAmps at 138 kV
10418167845042
2083733516710084
301,255502251151126
401,673669335201167
602,5101,004502301251
1004,1841,673837502418

Computed. Amps equal MVA times 1,000,000 divided by the square root of 3 times the line voltage.

New, surplus or remanufactured

A new build is made to your voltages and impedance but takes the longest, and power transformer lead times averaged 128 weeks in the second quarter of 2025 according to Wood Mackenzie. Surplus units are built for a project that changed and ship sooner. Remanufactured units suit a utility that needs a spare. Used units are priced at about 30 to 60 percent of new in one broker guide, and fully refurbished units with a warranty at 50 to 70 percent. We found no public price for mobile substations and we do not publish ours.

What to specify

The list below is what usually decides whether a listed unit fits your site.

  • MVA rating and cooling stages.
  • High side and low side voltages, and whether you need more than one.
  • Tap changer, load tap changing adds weight.
  • Switchgear on the trailer or separate, and the protection and control scheme.
  • Trailer count, axle loads and the permit route to your site.
  • Test reports and warranty you need on paper.

What to send for a quote

  • MVA and cooling
  • High side and low side voltage, and tap changer needs
  • Switchgear and protection on the trailer or separate
  • New, surplus or remanufactured
  • Site ZIP code and the date you need it energized

Common questions

How much does a mobile substation cost

We did not find public prices for mobile substations. Cost depends on rating, voltage, tap changer, switchgear and whether the unit is new, surplus or remanufactured. Ask for a delivered quote for the specific unit.

What is the largest mobile substation

Delta Star lists portable substations up to 100 MVA at 15 to 345 kV. A transformer industry presentation says mobile substations are generally 60 MVA or less because of road weight limits.

Mobile substation or mobile transformer

A mobile transformer is the transformer on a trailer. A mobile substation adds switchgear, protection and control so it can connect to a line and a feeder without separate equipment.

Should I rent or buy

Rent when the need has an end date. Buy when it recurs. See the mobile substation rental page.

Related pages

Sources

Market figures are public asking prices and published industry figures, dated where the source gives a date. They are not our prices. A quote from us is a delivered price for a specific unit.

CallGet a quote