Padmount Supply

Home / Products / Switchgear / Reclosers for sale

Reclosers for sale

A recloser is a self contained device that senses overcurrent, interrupts the fault and recloses the line. Because many overhead faults clear on their own, the trip and reclose cycle prevents outages. We quote new and used reclosers and their controls.

Updated November 17, 2026

Request a recloser quoteOr call 786 220 2801.

How a recloser works

Sources differ on how many overhead faults are temporary. EPRI says about 60 to 80 percent. One manufacturer catalog says about 80 to 95 percent. Either way, a recloser gives the line more than one chance before it locks out.

Ratings in general

One industry summary gives recloser ratings from 2.4 to 38 kV, for load currents from 10 to 1200 A and fault currents from 1 to 16 kA. Single phase units are grouped by voltage band and three phase units are rated through 38 kV.

TypeUseSource note
Single phaseProtects one phase, for single phase systems or lateralsG&W Viper SP is one example
Three phaseThe usual choice for three phase feedersOne source notes a recloser beats three fuse cutouts on a three phase circuit
HydraulicFluid filled mechanism, older designType W is an oil interrupter model
Electronic controlInterrupter plus separate electronic control and cableEaton NOVA with Form 6 is one example

Solid dielectric option

G&W says its Viper S solid dielectric pole recloser is rated up to 38 kV.

Price and availability

No price is printed here without a dated source. Send the voltage class, phase and control and we quote.

What to send for a quote

  • Single phase or three phase
  • System voltage and class
  • Continuous current and fault current
  • Control and cable
  • New or used
  • Delivery ZIP code and needed by date
Request a recloser quoteOr call 786 220 2801.

Common questions

What does a recloser do

It senses overcurrent, interrupts the fault current and recloses the line, so a temporary fault does not cause a lasting outage.

What voltage are reclosers rated for

One summary gives 2.4 to 38 kV, with three phase units rated through 38 kV.

Are hydraulic reclosers still used

Hydraulic reclosers are the original design. Modern electronic units pair the interrupter with a separate control.

How much does a recloser cost

Prices vary by voltage, phase and control. Request a quote.

Related pages

Sources

Market figures are public asking prices and published industry figures, dated where the source gives a date. They are not our prices. A quote from us is a delivered price for a specific unit.