Padmount Supply

Home / Products / Generators / Caterpillar generators, 3512, 3516, C32 and C18 sets

Caterpillar generators, 3512, 3516, C32 and C18 sets

Caterpillar builds diesel and natural gas generator sets from about 100 kW to 2.5 MW. This page sets out the Cat engines buyers ask for by name, 3512, 3516, C32 and C18, the 60 Hz ratings Cat and its dealers publish, and the gas sets that sit beside them. We source new, surplus and used Cat sets and quote them delivered.

Updated November 21, 2026

Request a Cat generator quoteOr call 786 220 2801.

Cat diesel engines and the kW they carry at 60 Hz

Cat quotes each set at a standby and a prime rating, and a family covers a range because the same engine is offered at several ratings. The figures below are what Cat and its dealers publish for 60 Hz. Ratings are in ekW at 0.8 power factor unless noted, and they change with fuel, emissions package and ambient, so confirm the sheet for the exact set.

EnginePublished 60 Hz rangeStandby and prime ratings listed
C18455 to 600 kW on one Cat pageAnother Cat listing shows standby 500 to 750 ekW and prime 455 to 680 ekW
C32Used in the 1,000 kW classToromont lists 1,000 kW standby and 910 kW prime at 60 Hz
3512890 to 1,250 ekWStandby 1,250 and 1,100 ekW, prime 1,135 and 1,000 ekW
3512CHigher rated versionCleveland Brothers lists 1,750 ekW standby and 1,600 ekW prime
3516C1,650 to 2,500 ekWStandby 2,500, 2,250 and 2,000 ekW, prime 2,250, 2,045 and 1,825 ekW

From the Cat and dealer pages listed under sources, read November 2026. Where two sources show different ranges for one engine we show both, since ratings differ by model version.

The GC model ladder

Cat's GC line is listed for emergency standby. Cat's product guide pairs the models with engines. The D350 and D400 GC use a C13, the D550 and D600 GC a C18, the D800 GC a C27, and the D1000 and D1250 GC a C32. All are listed as EPA stationary emergency rated. The US guide names the larger sets DE800S GC on the C27 and DE1000S GC and DE1250S GC on the C32, each with the low fuel consumption configuration.

Our 500 kW page covers the D500 GC on the C15 and the DE500 package, with fuel burn from the Cat sheets.

Cat modelEngineSize class
D350 GCC13350 kW
D400 GCC13400 kW
D500 GCC15500 kW
D550 GCC18550 kW
D600 GCC18600 kW
DE800S GCC27800 kW
DE1000S GCC321,000 kW
DE1250S GCC321,250 kW

Size class is the number in the model name. Confirm ekW on the spec sheet.

Cat natural gas generator sets

Cat's gas range pairs engine size with output. The G3512 is 1,000 kW, the G3516 is 1,500 kW and the G3520 is 2,000 kW at 0.8 power factor and 1,800 rpm. A G3516 set weighs 40,384 pounds, according to Cat. At the small end the DG200 GC is a 200 kW gas set, and the DG500 is a 500 ekW set on the CG18 engine. See our natural gas generator page for gas burn and the other makers.

Full load amps for common Cat sizes

Current is computed from the kW rating at 0.8 power factor. Use it for the transfer switch, breaker and cable.

SetkVAAmps at 480 V
350 kW438527
500 kW625752
600 kW750902
1,000 kW1,2501,504
1,250 kW1,5631,879
2,000 kW2,5003,007
2,500 kW3,1253,759

Computed. Amps equal kVA times 1,000 divided by the square root of 3 times the voltage.

Buying used Cat generators

Used Cat sets are listed across the range, from small engines to the 3512 and 3516. Ask for the hours, the overhaul record, the tier on the engine plate, a load bank test and the oil analysis. A set built for emergency use can carry an earlier tier than a set that has to run for prime power or peak shaving. See our guide to used generators for the full list of checks.

We did not find a dated public price list, so none is printed. For published new and used ranges at one size, see the 500 kW page.

What to send for a quote

  • Model, for example D500 GC or 3516C, or the serial number off the plate
  • Standby, prime or continuous rating, and kW or kVA
  • Voltage, for example 480Y/277
  • Diesel or natural gas
  • Emergency only or non emergency duty, and the emissions tier you need
  • New, surplus or used, and the hours you will accept
  • Transfer switch, paralleling gear or step up transformer needed
  • Site ZIP code and the date you need power
Request a Cat generator quoteOr call 786 220 2801.

Common questions

What kW is a Cat 3516 generator

Cat lists the 3516C at 60 Hz from 1,650 to 2,500 ekW, with standby ratings of 2,500, 2,250 and 2,000 ekW and prime ratings of 2,250, 2,045 and 1,825 ekW.

What kW is a Cat 3512 generator

Cat lists the 3512 at 60 Hz from 890 to 1,250 ekW, with standby 1,250 and 1,100 ekW and prime 1,135 and 1,000 ekW. A dealer lists the 3512C at 1,750 ekW standby and 1,600 ekW prime.

What is the Cat C32 generator output

Toromont lists a C32 set at 1,000 kW standby and 910 kW prime at 60 Hz.

What is the Cat C18 generator output

Cat lists the C18 at 60 Hz from 455 to 600 kW on one page, and another listing shows standby ratings of 500 to 750 ekW.

How many amps is a 1,000 kW Cat generator

A 1,000 kW set is 1,250 kVA at 0.8 power factor, which is 1,504 A at 480 V, three phase.

Do you sell used Cat generators

We source new, surplus and used Cat sets. Send the model or kW, voltage and hours you will accept and we quote what is available with its test history.

Related pages

Sources

Market figures are public asking prices and published industry figures, dated where the source gives a date. They are not our prices. A quote from us is a delivered price for a specific unit.

CallGet a quote