Padmount Supply

Home / Products / Generators / ASCO automatic transfer switches by series and amp rating

ASCO automatic transfer switches by series and amp rating

An ASCO automatic transfer switch moves a building load from the utility to the generator and back. The series you pick sets the amp range, the transition type and whether a bypass isolation switch is available. This page sets out the ranges ASCO publishes, and a table that turns generator size into the amps the switch has to carry. We source new and surplus ASCO switches and quote them delivered.

Updated November 18, 2026

ASCO series at a glance

ASCO sells its automatic transfer switches in families. The ranges below come from ASCO technical data and distributor pages, so confirm the exact catalog number against the ASCO publication before you order.

SeriesPublished rangeNotes from the sources
300 series30 A to 3,000 A in four framesOpen transition, with delayed transition on larger frames. A 1,200 A submittal lists bypass isolation as not applicable
4000 seriesAmp range not found in our sourcesSchneider Electric lists ASCO 4000 series on its automatic transfer switch category page, and ASCO withstand tables cover 300, 4000 and 7000 series
7000 series, low voltage30 A to 4,000 A, 115 V to 600 VDistributor pages. Optional load and source locations are listed for series 7000 only
7000 series, medium voltage1,200 A and 2,000 A to 3,000 A, 2,400 V to 13,800 VDistributor listing

Read November 2026 from the sources listed below. We print only the ranges those sources state.

ASCO 300 series frames

ASCO's 300 series technical data splits the line into frames. The smallest frame is open transition only. The larger frames are available as open or delayed transition. ASCO states that its open transition models transfer the load in less than 100 milliseconds.

FrameAmp rangeTransition
D30 A to 230 AOpen transition
J150 A to 600 AOpen or delayed transition
H800 A to 1,200 AOpen or delayed transition
G1,600 A to 3,000 AOpen or delayed transition

Which amp rating your generator needs

The switch has to carry the full load current of the generator, so start from the generator kVA. Generator kVA is kW divided by 0.8. The current at 480 volts is computed below, with the smallest 300 series frame whose published range reaches it. The 300 series tops out at 3,000 A, so a 2,000 kW set at 3,007 A needs the 7000 series, which ASCO distributors list to 4,000 A.

Treat the table as a starting point. Your engineer sets the switch rating from the breaker, the cable and the code.

GeneratorkVAAmps at 480 VSmallest 300 series frame that reaches it
100 kW125150D (30 A to 230 A)
150 kW188226D (30 A to 230 A)
250 kW313376J (150 A to 600 A)
500 kW625752H (800 A to 1,200 A)
750 kW9381,128H (800 A to 1,200 A)
1,000 kW1,2501,504G (1,600 A to 3,000 A)
1,500 kW1,8752,255G (1,600 A to 3,000 A)
2,000 kW2,5003,007Above the 300 series, 7000 series

Computed. Amps equal kVA times 1,000 divided by the square root of 3 times the voltage. A 500 kW set at 752 A sits just below the 800 A start of the H frame, so the next standard frame up carries it.

Reading an ASCO catalog number

Distributor submittals show catalog numbers such as H03ATSA31200NGXM, which a dealer lists as a 1,200 A ASCO automatic transfer switch. The catalog number encodes the series, the poles, the voltage and the options, so send the full number off the nameplate or the submittal and we quote the same switch or an equal. Do not guess a number from a series name.

Price and lead time

ASCO does not publish prices and we do not print one without a dated source. Lead time on a new switch follows the factory schedule, and we state it on the quote. A surplus or used switch that already exists can ship once it is tested. Send the amps, voltage and options and we quote new, surplus and equal switches and say which is which.

Matching the switch to the rest of the system

A transfer switch sits between the utility service, the generator and the load, so the generator breaker, the cable and the switch all have to agree on current and fault rating. Static transfer switches are a different product, used for critical loads where a transfer must be near instant. See our static transfer switch page, and our generator pages for the set that feeds the switch.

What to send for a quote

  • Full catalog number from the nameplate, or the series you want
  • Amp rating and voltage, for example 800 A at 480 V
  • Number of poles, three or four, and phase
  • Open, delayed or closed transition
  • Bypass isolation required or not
  • Short circuit withstand rating needed at the site
  • New, surplus or used
  • Site ZIP code and the date you need it

Common questions

What amp ratings do ASCO automatic transfer switches come in

ASCO's 300 series spans 30 A to 3,000 A in four frames, and distributor pages list the low voltage 7000 series from 30 A to 4,000 A at 115 V to 600 V.

What is the difference between ASCO 300 and 7000 series

Per the sources we read, the 300 series is built around open transition with delayed transition on larger frames, and the 7000 series covers a wider range to 4,000 A and offers optional load and source locations.

Does the ASCO 300 series have bypass isolation

A 1,200 A ASCO 300 series submittal lists bypass isolation as not applicable. Ask us for the series that offers it.

What size transfer switch does a 500 kW generator need

A 500 kW set is 625 kVA, which is 752 A at 480 V, so the switch must be rated above that. The next 300 series frame up is the H frame, 800 A to 1,200 A.

Is there an ASCO medium voltage transfer switch

Distributor listings show a medium voltage 7000 series at 1,200 A and 2,000 A to 3,000 A for 2,400 V to 13,800 V.

How much does an ASCO transfer switch cost

ASCO does not publish prices. Request a quote with the amps, voltage and options.