Main breakers for switchboards

A main breaker is the device that switches and protects a whole switchboard. For a 1200 A main the choice is a molded case or insulated case breaker, and above 3000 A it is usually a power breaker. We source new and reconditioned main breakers and switchboards and quote them delivered.

Updated November 17, 2026

Request a main breaker quoteOr call 786 220 2801.

Frames by maker

Published frame ranges read in November 2026 are below. Always confirm the exact frame, trip unit and short circuit rating against the nameplate.

LinePublished range
Schneider PowerPact P frame, molded case100 to 1200 A
Schneider MasterPacT MTZ1, UL 489 rating tableincludes a 1200 A frame rating
Eaton Magnum SB insulated case800, 1200, 1600, 2000, 2500 and 3000 A frames
Eaton Magnum DS power breaker1200 A up to 5000 A
ABB Power Break II insulated case200 to 4000 A
Siemens WL insulated caseup to 4000 A

Which type for a 1200 amp main

A molded case breaker is the lowest cost choice and tops out at 1200 A in the Schneider P frame family. An insulated case breaker adds a higher short circuit rating, adjustable trip settings and in some versions drawout mounting. Fixed and drawout versions both exist, so say which you need and match the switchboard section.

Above 3000 A the Eaton insulated case line stops, so larger mains are power breakers. The 4000 amp switchboard page covers that range.

Sizing the main

Start from the transformer. A 1000 kVA unit at 480 V draws about 1,203 A and a 1500 kVA unit about 1,804 A. Then apply your code margin, the available fault current at the lineup and any ground fault requirement. Our kVA to amps calculator gives the full load figure for any size.

New or reconditioned breakers

Reconditioned breakers keep an old lineup running without a rebuild. They need a matching frame, a tested trip unit and a warranty. Our used switchgear page lists the test and warranty norms we ask for.

What to send for a quote

  • Breaker maker, frame and catalog number from the nameplate
  • Amp rating and trip unit type
  • Fixed or drawout mounting
  • Short circuit rating in kA and system voltage
  • Switchboard maker and line the breaker must fit
  • New or reconditioned and the date needed
  • Delivery ZIP code
Request a main breaker quoteOr call 786 220 2801.

Common questions

What is the largest molded case main breaker

Schneider lists its PowerPact P frame from 100 to 1200 A. Other makers list larger molded case frames in their own catalogs.

What is the difference between insulated case and power breakers

Both are used as switchboard mains. Insulated case breakers are usually lower cost and smaller. Power breakers go to higher ratings, with Eaton Magnum DS covering up to 5000 A.

Can a 1200 amp main breaker be reconditioned

Yes, when the frame and trip unit are tested and the unit matches the switchboard section. We source tested units.

How do I find the breaker I need

Send a photo of the nameplate and the existing breaker label. The catalog number gives the frame and rating.